Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes.
Learn More
Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards.
Learn More
Validating the specifications, value and safety of your raw materials, products and assets.
Learn More
Formally confirming that your products and services meet all trusted external and internal standards.
Learn More
The new EU standard EN55035, which may replace the existing multi-media equipment applicable standards EN55020 and EN55024 and their amendments, has been included in the RED official journal on December 15, 2017.
The new EU standard EN55035 has been included in the RED official journal on December 15, 2017 for radio broadcast receiver, i.e. AM/FM/DAB radio.
What is the difference of the standard comparing with EN55020 and EN55024? Let Intertek Hong Kong quickly and accurately show you to understand EN55035.
Multimedia equipment standards include the former EN55020 (AV) products and EN55024 (ITE) products, also include professional use multimedia products.
The EN55035 test requirements are not a simple overlay of the EN55020 and EN55024 test requirements. Here, let’s clearly understand EN55035 by comparing the requirement differences of the key test items:
Test Item | Test Requirements Comparison | ||
EN 55035 | EN 55020 | EN 55024 | |
ESD | +/-4KV for Contact discharge
+/-8KV for Air discharge 10 of each polarity | +/-4KV for Contact discharge +/-8KV for Air discharge 10 of each polarity | +/-4KV for Contact discharge +/-8KV for Air discharge 25 of each polarity |
Test Item | Test Requirements Comparison | ||
EN 55035 | EN 55020 | EN 55024 | |
R/S | 80MHz-1000MHz 1800MHz, 2600MHz, 3500MHz, 5000MHz | 900MHz, 790-862MHz | 80MHz-1000MHz |
EFT | +/-1KV for ac
mains port
+/-0.5KV for analogue/ digital data ports and DC network power port | Only +/-1KV for ac mains port | +/-1KV for ac
mains port +/-0.5KV for analogue/ digital data ports and DC power port |
Surge |
| N/A | signal ports
and telecommunication ports:
|
CS | 0.15MHz-10MHz:
3V
10MHz-30MHz: 3V to 1V 30MHz-80MHz: 1V | N/A | 0.15MHz-80MHz: 3V |
Power frequency magnetic field | 1A/m | N/A | 1A/m |
Voltage dips & Short interruptions - Voltage dips | Residual
voltage: < 5%
Number of cycles 0.5 Residual voltage: 70% Number of cycles: 25 for 50 Hz; 30 for 60 Hz | N/A | Residual
voltage: < 5%
Number of cycles 0.5 Residual voltage: 70% Number of cycles: 25 for 50 Hz; 30 for 60 Hz |
Voltage dips & Short interruptions - Voltage interruptions | Residual voltage: < 5 Number of cycles: 250 for 50 Hz, 300 for 60 Hz | N/A | Residual voltage: < 5 Number of cycles: 250 for 50 Hz, 300 for 60 Hz |
Test Item | Test Requirements Comparison | ||
EN 55035 | EN 55020 | EN 55024 | |
Broadband impulse
noise disturbances, repetitive - Impulse Frequency Test level | 0.15MHz to 0.5MHz
107dBuV; 0.5 MHz to 10MHz; 107dBuV to 36dBuV; 10 to 30MHz 36dBuV to 30dBuV | N/A | N/A |